    RCZ-6C3 Six-Cup Medicine Dissolving Instrument

    • RCZ-6C3 type medicine dissolving instrument is a new product prepared in accordance with specification of chinese Pharmacopoeia 2000 edition,its indexes of main characteristics excess same sory of product at home.
    • Up-down driver with double upright pillars adopted so as to be beautifully fashioned layout,operate conveniently and get high autoimmunization,projection about the most new of circuit applied,property outstanding,measured datum precise.
    • Beside human body imitated by tablet to make trial,degree of dissolution about pill tablet and capsule to be measured,also can be sued in food and cosmetic professions for measuring dissolution relative to them.
    • It can be widely applied to medicine examining section.College of medical science,department of resaearches as well as laboratory.

    Application

    RCZ-6C3 type medicine dissolving instrument is a new product prepared in accordance with specification of chinese Pharmacopoeia 2000 edition,its indexes of main characteristics excess same sory of product at home.Up-down driver with double upright pillars adopted so as to be beautifully fashioned layout,operate conveniently and get high autoimmunization,projection about the most new of circuit applied,property outstanding,measured datum precise.Beside human body imitated by tablet to make trial,degree of dissolution about pill tablet and capsule to be measured,also can be sued in food and cosmetic professions for measuring dissolution relative to them.It can be widely applied to medicine examining section.College of medical science,department of resaearches as well as laboratory.

    Technical Parameter

    ModelRCZ-6C3
    Limit of thermo conrolling36.5-38.5℃(digital display)
    Speed Limit25-200rpm(digital display)
    Accuracy of thermo controlling±0.3℃
    Tolerance of stable speed<±4%
    Wagging width at rotary basket rotating<±1.0mm
    Syn axis rake between rotary axis and flask<±1mm
    Wagging width of up-down and left-right on external part at paddle rotating<±0.5mm
    Number of flask6 p